土木学会論文集B1(水工学)
Online ISSN : 2185-467X
ISSN-L : 2185-467X
水工学論文集第64巻
INFLUENCE OF WATER CONTROL FACILITIES ON THERMAL STRATIFICATION OF OGOUCHI RESERVOIR FOR 58 YEARS
Maurice DUKAKatsuhide YOKOYAMATetsuya SHINTANIKei IGUCHIAkira KOIZUMIHiromi IWASAKIToshiaki UENOTetsuya CHIBA
著者情報
ジャーナル フリー

2019 年 75 巻 2 号 p. I_685-I_690

詳細
抄録

 Selective withdrawal (SW) systems regulate the temperature of water released downstream of dam while vertical curtains (VC) prevent phytoplanktons from the shallow upstream reaches to disperse into the main reservoir. These water control facilities can affect the reservoir’s temperature distribution. Through long term analysis of Ogouchi’s temperature data together with numerical simulation, this paper explains the variation in temperature profiles during the three distinct periods in the reservoir’s operation namely, (1) deep penstock withdrawal (DPW), (2) purely SW and (3) combined SW and VC. Schmidt’s Stability Index (SSI) and Thermocline Strength Index (TSI) were computed to define thermal stratification. DPW promotes mixing and makes the reservoir generally warmer while SW creates a strong thermocline (high TSI) and when combined with VC, increases thermal stability (high SSI). Using 3-D hydrodynamic simulation, the conditions were successfully replicated. Results showed that outflow location and facilities largely affect the temperature and velocity profiles and the mixing and transport of river water within the reservoir.

著者関連情報
© 2019 Japan Society of Civil Engineers
前の記事 次の記事
feedback
Top