Journal of System Design and Dynamics
Online ISSN : 1881-3046
ISSN-L : 1881-3046
Papers
Dynamic Visco-elastic Buckling Analysis for Airway Model
Kiyoshi BANDOKenkichi OHBAYuta YAMANOI
著者情報
ジャーナル フリー

2010 年 4 巻 1 号 p. 189-199

詳細
抄録

In order to clarify the mechanism by which the lung airway narrows during an asthma attack, dynamic buckling analysis of the wall was conducted. The wall was modeled using a visco-elastic thin-walled circular cylinder of the Voigt model for the planestress state. A governing equation for dynamic buckling was derived, and in the equation, the contraction of smooth muscle was replaced by uniform inward transmural pressure. The non-dimensional parameters for the buckling wave number n were nondimensional retardation time τ, non-dimensional increasing velocity of inward transmural pressure β, thickness radius ratio α2, radius length ratio η, density ratio ζ, and Poisson's ratio ν. The validity of the theoretical model was confirmed by comparing the calculated wave number with that obtained from the experiment, in which a silicone rubber tube blended with silicone potting gel was used as the in vitro airway model. In addition, the wave number n increased with β. It was necessary to consider the damping effect of the tube model or the airway wall, and n increased by 1.5 to 2 due to the additional mass effect of surrounding tissues of the basement membrane in the airway wall.

著者関連情報
© 2010 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top