45 種々の文献データに基づくLiB劣化モデルの作成と住宅負荷想定時における理論劣化モデル式との違い
*小川 雄気松尾 廣伸
著者情報
会議録・要旨集 フリー

p. 155-158

詳細
抄録

To reproduce the LIB battery performance, data from various literatures was collected and fitted to the main deterioration factor characteristic graphs. As a result, it was confirmed that the deterioration factor FEC has a power function, the temperature has a composite function of the Arrhenius and inverse Arrhenius equations, and the C rate has a cubic function. By incorporating these functions, a deterioration model with a maximum RMSPE of 4.97 % was created. In addition, the model described in the book and the created model were evaluated in terms of deterioration transition and in a 15-year charge/discharge simulation assuming an ordinary home.