抄録
Total knee replacement has been performed in 134 joints of 101 patients from 1974 to 1985. The factors that influenced the range of motion after total knee replacement were analyzed in 70 of these joints. It was found that the type of implants, the preoperative range of motion and the flexion contracture had an influence on the postoperative range of motion, while the preoperative diagnosis, the time of starting physical therapy, the postoperative femorotibial angle, and the tilt of each component did not.