生体医工学
Online ISSN : 1881-4379
Print ISSN : 1347-443X
ISSN-L : 1347-443X
研究
実心臓に基づく形状及び円筒形状を用いた左心室拍動シミュレーションにおける収縮末期応力分布の比較
高田 康弘陸 建銀嶋吉 隆夫石川 覚志天野 晃小寺 秀俊松田 哲也
著者情報
ジャーナル フリー

2006 年 44 巻 4 号 p. 613-620

詳細
抄録
We evaluated the stress distribution in a cylindrical model and a shape model obtained from human heart using two different fiber orientations. For both orientation models, the results showed large differences between the stress distribution in the cylindrical model and the measurement-based shape model. These results suggest that stress distribution is highly dependent on the model geometry, and the usage of a measurement-based shape model is important for evaluating left ventricular (LV) wall stress distribution. This fact may have some influence on the reported homogeneity of stress distribution in an anatomical fiber orientation model that uses a mathematical symmetric shape model.
著者関連情報
© 2006 社団法人日本生体医工学会
前の記事 次の記事
feedback
Top