1次元弾性要素配列を用いた針のしなりと生体組織の変形の実時間シミュレーション
小石 毅森田 慎也中口 俊哉川口 泰弘津村 徳道三宅 洋一
著者情報
ジャーナル フリー

2008 年 46 巻 6 号 p. 629-646

詳細
抄録
In percutaneous puncture simulation, the finite element method is usually used to compute the needle bend and tissue deformation. This method, however, tends to be not suitable for real-time applications such as training systems due to its high computational cost. In this paper, we propose a novel deformable model with a low computational cost. The proposed model reproduces needle bend and tissue deformation in the direction perpendicular to the long axis of the needle. The proposed model consists of a soft tissue deformation model based on the Long Element Method (LEM) and a needle bending model which is designed to be consistent with the tissue model. The parameters for both models are put in the same simultaneous equation to be solved for the simulation. We verified that the proposed model shows a low computational cost by the computer simulation. The accuracy of the model was also evaluated by the experiment using needles and tissue phantoms. The experimental result using only needles showed that a bend could be estimated by the pre-optimized parameters. The optimized parameters were available even if different displacement was given to the manipulated point of the needle.
著者関連情報
© 2008 社団法人日本生体医工学会