Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Influence of the Connecting Passage of a Low Pressure Indicator on Recording
Fujio NAGAO, Yuzuru SHIMAMOTO, Hiroyuki NAGANO, Yoshiaki UENO
著者情報
ジャーナル フリー

1963 年 6 巻 21 号 p. 78-85

詳細
抄録
Since the pressure sensitive diaphragm of a low pressure indicator is usually made large to increase the gain per unit pressure, it is difficult to arrange the diaphragm to be flush with the inner surface of the wall, to which the indicator is fixed. The error, resulting from the passage leading from the inner surface to the diaphragm, increases with the decrease in the resonant frequency of connecting passage. The authors have theoretically and experimentally investigated the effect of the connecting passage on the accuracy of the pressure measured. They found out that the resonant oscillation in the connecting passage, which occurs due to the cross-sectional area of passage being made large to raise the resoant frequency, can be successfully avoided by fitting the passage with a damper such as a throttle. The delay of the measured pressure-change due to the damper is permissibly small.
著者関連情報
© The Japan Society of Mechanical Engineers
前の記事 次の記事