JSME International Journal Series B Fluids and Thermal Engineering
Online ISSN : 1347-5371
Print ISSN : 1340-8054
ISSN-L : 1340-8054
PAPERS
Sound Suppression of Laminar Separating Flow over Cavity
Seiichiro IZAWAHiroshi MAITAOsamu TERASHIMAAo-Kui XIONGYu FUKUNISHI
著者情報
ジャーナル フリー

2006 年 49 巻 4 号 p. 1092-1097

詳細
抄録
A passive control of aerodynamic noise generated by a laminar separating flow over a cavity is carried out in a wind tunnel test and by numerical simulation, using a thin plate inserted into the cavity as a passive flow-controlling device. In the experiment, a noise suppression effect up to 14dB is achieved by placing a plate in a proper location. It is shown that a plate of smaller vertical size is more effective. In the numerical simulation, it is shown that the location where the shear layer rolls up and the path of vortices are both very sensitive to plate position.
著者関連情報
© 2006 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback