JSME international journal. Ser. 2, Fluids engineering, heat transfer, power, combustion, thermophysical properties
Print ISSN : 0914-8817
Instability in a Cavitating Centrifugal Pump
Kazuyoshi YAMAMOTO
著者情報
ジャーナル フリー

1991 年 34 巻 1 号 p. 9-17

詳細
抄録
It is known that low cycle system oscillation tends to occur in a piping system connected to a high-speed pump in which cavitation is occurring. The majority of papers on this subject discuss attempts at predicting this occurrence through linear transfer matrices of cavitating pumps, both experimentally and theoretically. There are, however, few papers that discuss low-cycle system oscillation occurring in reverse flow at a pump inlet. The following discusses three types of low-cycle system oscillation, which are defined by synthetic studies. The effects of NPSH, pump flow rate, rotational speed, and pipe length are clarified experimentally.
著者関連情報
© The Japan Society of Mechanical Engineers