JSME international journal. Ser. 2, Fluids engineering, heat transfer, power, combustion, thermophysical properties
Print ISSN : 0914-8817
Measurements of OH Concentration and Temperature in Diffusion Flame by Excimer Laser-Induced Fluorescence and Rayleigh Scattering
Masaharu KOMIYAMADaisei KEMAToshimi TAKAGI
著者情報
ジャーナル フリー

1991 年 34 巻 2 号 p. 248-252

詳細
抄録
OH fluorescence induced by a XeCl excimer laser was detected in a laminar diffusion flame. The OH concentration and temperature in the flame were estimated by OH fluorescence and Rayleigh scattering. The results obtained are as follows. (1) The spectrum of OH fluorescence was numerically simulated by rate equations taking account of many absorption transitions excited by the XeCl excimer laser and it predicted the experimental results well. (2) Relative and absolute OH concentration were estimated by the measured fluorescence and rate equations. (3) Rayleigh scattering was separated from OH fluorescence to measure flame temperature. The measured temperature agreed with that obtained by the use of Rayleigh scattering by an argon ion laser.
著者関連情報
© The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top