計算力学講演会講演論文集
Online ISSN : 2424-2799
セッションID: OS-1809
会議情報

MRI流体計測データ同化における部分体積効果の影響
*上田 架岩田 和真大谷 智仁和田 成生
著者情報
会議録・要旨集 認証あり

詳細
抄録

Phase-contrast magnetic resonance imaging (PC-MRI) is a powerful tool for flow measurements in vivo and provides a volume-averaged velocity vector in each voxel of the MRI images (partial volume effect: PVE). Several flow data assimilation approaches between MRI and computational fluid dynamics (CFD) simulations have been proposed, while the observation model of the MRI velocity fields is not well established and the PVEs of the MRI images have been not fully considered. Therefore, this study evaluates the impacts of the PVE on MRI flow data assimilation. The flow data assimilation was formulated by minimizing the error between MRI and CFD flow velocity fields with respect to the inlet boundary following the adjoint variable method. Here, we considered two types of error functions with and without PVE and conducted numerical examples of the two-dimensional steady flow fields with three cases of MRI resolutions. Numerical examples successfully demonstrated that the effects of PVE are non-negligible in the case of low-resolution MRI images.

著者関連情報
© 2023 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top