Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 105
会議情報
105 発電用新型炉へ適用する3次元免震システムの研究 : 単独ローリングシール型:その2(免震構造2,OS-12:耐震・免震・制振(1))
梅木 克彦蔭山 満伊庭 力日野 吉彦高橋 健司生玉 真也
著者情報
会議録・要旨集 フリー

詳細
抄録
This paper shows the overview of the test results conducted to confirm the applicability of the proposed three-dimensional seismic isolation system to the actual advanced nuclear power plant. The tests consist of the shaking table test for the system and the integrity tests for the air spring. The integrity tests consist of the pressure test, the air permeability measurement test of the rubber sheet that composes the air spring, and the failure mode confirmation test. From those tests, it was understood that the proposed system could exhibit the seismic isolation function sufficiently, the air spring could resist the design pressure for 60 years in plant life, and the air spring has no catastrophic failure mode.
著者関連情報
© 2004 一般社団法人 日本機械学会