Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 511
会議情報
511 超大型振動台シミュレータの精度向上に関する研究
永山 貴教田川 泰敬林 洋一梶原 浩一
著者情報
会議録・要旨集 フリー

詳細
抄録
A 3-D Full Scale Earthquake Testing Facility (E-Defense) was built in Miki Hyogo in January 2005 by National Research Institute for Earth Science and Disaster Prevent (NIED). The E-Defense makes it possible to do full-scale 6 DOF shaking tests. The E-Defense reproduces the earthquake wave which was actually observed. The test body for the E-Defense is assumed about 1200 tons while the shaking table mass is about 750 tons. The mass ratio becomes substantially large, and greatly influences shaking performance. Therefore simulation tools are needed which allow us to understand shaking performance in advance. In this research, we identify the component of E-Defense, and we make simulation tools. And it aims at the development of simulation tools that can verify the performance.
著者関連情報
© 2008 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top