会議情報

単独建物のための内部4棟連結制振システムの研究
髙橋 洋行豊田 紘行高野 崇弘渡辺 亨背戸 一登
著者情報
会議録・要旨集 フリー

詳細
抄録

The connected control method (CCM) utilized reaction force between buildings as damping force by using connecting springs and dampers. The effectiveness of CCM has already been established in previous studies. In this paper, integrated connected control method (ICCM) with an experimental high-rise building split into four substructures is presented for a vibration control method to mitigate structural vibration by using internal damping force by CCM. To examine the effectiveness of ICCM, an experimental structure model split into four substructure is build and four dampers are introduced to realize experimental ICCM. Using this model, the effectiveness ICCM is investigated through computer simulations and experiments.

著者関連情報
© 2016 一般社団法人 日本機械学会