歩行時の足部温度予測のためのゴム底繰り返し圧縮による熱挙動計測
松谷 俊輝島崎 康弘井上 貴浩
著者情報
会議録・要旨集 フリー

詳細
抄録

This study had been conducted to predict foot temperature and to understand thermal behavior of rubber sole under cyclic compression. Three EVA samples of different compression characteristics were used in this study. In cyclic compression experiment, temperature changes of EVA samples were measured. As a result, temperature elevation of EVA16 was higher than other samples. In the stepping experiment, temperature changes of foot and EVA were measured. As a result, EVA08 and EVA16 showed different temperatures change tendency. Through two experiments, EVA of high tanδ showed high temperature elevation. Numerical simulation for predicting of foot temperature was built by consideration of the internal heat generation of EVA. As a result, numerical simulation qualitatively agreed with the stepping experiment. So numerical simulation in this study could show tendency of foot temperature elevation by EVA of different tanδ. However, temperature in numerical simulation was slightly higher than measured temperature. Result of numerical simulation in this study was indicated the need to consider radiation of foot and EVA.

著者関連情報
© 2016 一般社団法人 日本機械学会