摩擦/粘性ダンパとすべり基礎を併用した薄板軽量形鋼造フレームの振動台加振実験
その2リンク式流体慣性ダンパを設置した場合
*渡井 一樹曽田 五月也宮津 裕次脇田 健裕
著者情報
会議録・要旨集 認証あり

詳細
抄録

This study is on a shaking table test of Light-gauge Cold-formed Steel Frame. The test frame is a three-story frame scaled to nearly 1/2. In this paper, we show the test results and seismic response control effect using the friction damper and Linked Fluid Inertia Mass Damper (LFIMD). The friction damper is installed in the shear wall, and the LFIMD is installed between the adjacent floors. We designed a LFIMD that is constructed by three cylinders connected with link tubes, to simultaneously control story deflection of a three-story frame.