主催: 一般社団法人 日本機械学会
会議名: Dynamics and Design Conference 2019
開催日: 2019/08/27 - 2019/08/30
After the Great East Japan Earthquake of 2011 and the Kumamoto Great Earthquake of 2016, it is becoming necessary to upgrade earthquake countermeasure technology for further infrastructure conservation. We have been developing a high-performance three-dimensional seismic isolation system. This paper describes the full-scale seismic excitation experiments on a new three-dimensional seismic isolation device using coil springs and the negative stiffness linkages in parallel on the air levitation pads. As a result of the excitation experiment by using the seismic waves of KiKnet Mashiki-Machi (the Kumamoto Earthquake), the acceleration responses of the seismic isolation system were reduced to 1/10 in the horizontal direction and 1/3 in the vertical direction. Air levitation pads were designed by the fluid bearing formula and confirmed its validity by an experiment. The levitation height during excitation was monitored and we found that there was no contact with the floor surface even at high acceleration.