Dynamics & Design Conference
Online ISSN : 2424-2993
会議情報

ウェアラブルセンサシステムを用いた 関節トルク推定における誤差低減に関する研究
廣瀬 圭近藤 亜希子辻内 伸好伊藤 彰人
著者情報
会議録・要旨集 認証あり

p. 431-

詳細
抄録

This study aims to error reduction in estimation of joint torque using wearable sensor system. The wearable sensor system consists of wearable motion sensor installing the inertial and magnetic field sensors and wearable force plate installing several compact force sensors and inertial and magnetic field sensors. The wearable motion sensor outputs the angular velocity, the acceleration, and magnetic field, and the wearable force plate outputs the 6-axis force components and the motion sensor output. We conducted the measurement experiment of gait analysis using the wearable sensor system and the optimal motion capture system. We established the compensation method of error reduction in the effect by attaching on skin and clothes. This method was assumed the effect of error elements by using the spring and damping elements. We compared the posture information of knee joint in the results of without compensation and with compensation. The analytical results of the Roll angle indicated the effectiveness of this method.

著者関連情報
© 2020 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top