Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 219
会議情報

機器・配管系の塑性化を考慮した簡易的な耐震設計手法の検討
*落合 兼寛
著者情報
会議録・要旨集 認証あり

詳細
抄録

The applicability to Japan of the American Society of Civil Engineers seismic design standard (ASCE/SEI 7-22) is examined with respect to a simple seismic design method considering the plastic region of machinery and equipment. Response analyses were conducted for seismic waves recorded in Japan using a simple, end-supported, 5-Masses model with bilinear force-deflection characteristics, and the following results were obtained: (1) When the yield capacity is set using the maximum acceleration value of the input wave as the static load, an element ductility factor of 3 to 5 is expected. (2) The standard’s recommends value of 2/3 of the response reduction factor can be appropriate for flexible systems, but for systems with high natural frequencies, it is necessary to consider the other effects such as an overstrength factor in addition to the effect of energy absorption by plasticization.

著者関連情報
© 2023 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top