昇降機・遊戯施設等の最近の技術と進歩技術講演会講演論文集
Online ISSN : 2424-3183
会議情報
103 塑性緩衝器のエレベーターシステムへの適用検討 : 円筒座屈式緩衝器の性能確認
安部 貴宮田 弘市重田 政之大亦 絢一朗納冨 充雄伊東 菜摘
著者情報
会議録・要旨集 フリー

p. 9-12

詳細
抄録
In order to relax the impact to the elevator system when the car or counter weight collides with the terminal, the buffers have been installed. In this research, the application examination of a small, cheap shock absorber utilizing plastic deformation to the elevator system is done. Moreover, it proposes the cylinder buckling type buffer as a plasticity shock absorber, and the static characteristic is confirmed by the FEM analysis and the examination. In addition, the buffer characteristic of this shock absorber is confirmed from the dynamic test with impact testing machine, and the utility is confirmed.
著者関連情報
© 2003 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top