環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 207
会議情報
207 廃棄物処理システムにおける防災対策について : 混合燃料に対する着火抑制効果(再資源化・再利用)(廃棄物処理技術)
永田 勝也田中 潤小野 弘喜坪井 康宏板谷 真積
著者情報
会議録・要旨集 フリー

詳細
抄録
Gasification melting system is necessary for recycling and volume reduction of solid waste. However, many explosions accidents are caused by combustible gases filled in shredding or gasification melting process from gas cylinder and spray-can mixed within bulky waste. In this experiment, inhibition of ignition of mixed fuel composed of C_3H_8, CO and H_2, N_2 or CO_2 as the inert gas is analyzed using a spark plug as the source of ignition. As a result, 1) according to the ignition limit calculated by Le Chatelier's formula, on some condition, there is a possibility of explosion accidents, 2) adiabatic flame temperature is constant at about 1500K under the condition of the ignition limit, and the ignition limit is valued by the product of organic radical and O containing radical, 3) Using the heat balance simulation, if DME or Cyclopentane is added to combustible gases, there is risk of explosion accidents.
著者関連情報
© 2001 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top