抄録
Microbubbles have been already used as ultrasound contrast agents to visualize microcirculation system. They are also expected to be used for the drag delivery agent. For these bubbles, important requirements are their size and functionality such as carrying drugs and staying stability in vivo. We have been developing a microbubble generation system using microchannels. Advantages of the method using microchannels are to generate small- and monodisperse-size microbubbles with the wide variety of choice in both liquid phase and gas phase. In the present study, microbubbles are generated using T-junction type microchannel. We have designed the channel shape to reduce the bubble size. The improvement of the shape has enabled us to generate the smaller microbubble whose diameter is 6.1|im. Moreover, it is confirmed that smaller bubbles are generated with the increase of viscosity. In addition, we have developed a new type microchannel for the surface coating of a microbubble.