In this study, knowing about behavior of virus droplets under the indoor environment by combining droplet nuclei infection. which is difficult to prevent with CFD is the object・In concrete terms, temperature and humidity, radius of virus droplet, viability of virus as parameters which has an influence on behavior and infection of virus introduce into 7[!ransmission Simulation. As a result, many virus droplets are different from airflow under the indoor environment.