流体工学部門講演会講演論文集
Online ISSN : 2424-2896
セッションID: GS11
会議情報

体外摘出肝臓灌流における臓器の酸素動態と流動特性
森戸 規之小原 弘道松野 直徒絵野沢 伸
著者情報
会議録・要旨集 フリー

詳細
抄録

The machine perfusion (MP) techniques have extensively studied to preserve and resuscitate donated organ for organ transplantation. The MP technique is able to not only supply the organ with nutrition and oxygen continually through the preservation solution but also evaluate the liver viability. However, the perfusion machine that can evaluate liver viability is not yet established. In this study, the evaluation index was suggested by correlation between oxygen consumption dynamics and the liver function using porcine donated livers. As a result, the liver, which have oxygen consumption gradient of the low level was higher hepatic artery pressure and aspartate amino transferase of effluent enzyme. Therefore, oxygen dynamics of the liver during machine perfusion associated with the liver function and can used for the organ evaluation index before implantation.

著者関連情報
© 2016 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top