流体工学部門講演会講演論文集
Online ISSN : 2424-2896
セッションID: OS15-15
会議情報

複数の分岐・合流部のある管内流におけるプラズマアクチュエータの設置位置の影響
*金原 大地佐川 貴浩佐野 正利
著者情報
会議録・要旨集 認証あり

詳細
抄録

An experimental study is performed for multiple-passage duct flows. The multiple-passage is a reverse flow type, and consists of the five branch ducts. The dielectric barrier discharge plasma actuator (PA) is used for the flow control of reverse flow passages. The duct flows are investigated from the view point of flow uniformity and pressure loss reduction. The location in which the actuator is installed is changed in three positions of the outside wall at the inlet manifold and the outlet manifold. Reynolds number based on the bulk velocity and hydraulic diameter at the inlet duct are varied from 6.0×102 to 2.0×103. The results show that the pressure loss decreases and the flow rate in each branch duct passages improves by the effect of induced flow with the PA. The effect is remarkable when the PA is installed near the first branch of the inlet manifold.

著者関連情報
© 2018 一般社団法人 日本機械学会