ICONE11-36211 ADVANCED EVALUATION METHOD OF SG TSP BEC HOLE BLOCKAGE RATE
Hiroyuki IZUMIDAYasuyuki NAGATAYutaka HARADARyuji MURAKAMI
著者情報
会議録・要旨集 フリー

p. 10-

詳細
抄録
In spite of the control of the water chemistry of SG secondary feed-water in PWR-SG, SG TSP BEC holes, which are the flow path of secondary water, are often clogged. In the past, the trending of BEC hole blockage rate has conducted by evaluating ECT original signals and visual inspections. However, the ECT original signals of deposits are diversified, it becomes difficult to analyze them with the existing evaluation method using the ECT original signals. In this regard, we have developed the secondary side visual inspection system, which enables the high-accuracy evaluation of BEC hole blockage rate, and new ECT signal evaluation method.