Proceedings of the ... International Conference on Nuclear Engineering. Book of abstracts : ICONE
Online ISSN : 2424-2934
2019.27
セッションID: 1887
会議情報

STUDY ON THE OPERATION CHARACTERISTIC EFFECT OF ONCE-THROUGH STEAM GENERATOR IN START-UP FOR THE FEEDWATER PROJECT
*Xia-ming KongWei WangYong ChenHai-bo MengJie PangShuai-jun Li
著者情報
会議録・要旨集 認証あり

詳細
抄録
Because both special structure and the complicated vapor-liquid two-phase flow process of the once-through steam generator (OTSG) is limited, the OTSG needs to set a special start-up system. The simulation model of the OTSG is established after reasonable simplifying the system. And the operational characteristics of the different feedwater projects on dry start-up condition are simulated based on JTopmeret. The result shows the steam parameter fluctuates wildly and the flow instability affects evidently for the dry start-up project with the constant feedwater, which induce large fluid pressure fluctuation and vibration. For the variable feedwater project, the operation of the start-up system is more stable and has higher efficiency of using the new steam. And the vibration and pressure fluctuation is lower.
著者関連情報
© 2019 The Japan Society of Mechanical Engineers