抄録
The article presents the heat transfer and friction factor characteristics of turbulent flow in a uniform wall heat flux tube inserted with delta-winged dual twisted tapes. The typical dual twisted tapes (DTs) with constant twist ratio of y/W = 3.0 and delta-winged dual twisted tapes with delta-winged attack angle of α = 30° and β = 30° were carried out. Influences of the delta-winged arrangements in (1) the parallel direction (DT-PW) and (2) the counter direction (DT-CW) on the thermal performance characteristics were also described. The experimental results found that the use of the dual twisted tapes with parallel wing arrangements (DT-PW) provide the heat transfer higher than those the typical dual twisted tapes (DTs) and dual twisted tapes with counter wing arrangements (DT-CW) around 6.6-7.3% and 5.5-8%, respectively, due to stronger of dual-swirling/turbulent flow leading to better fluid mixing between the core and near tube walls while the friction factor is increasing up to 10.9 times above the plain tube. The typical dual twisted tapes (DTs), dual twisted tapes with parallel wing arrangements (DT-PW) and dual twisted tapes with counter wing arrangements (DT-CW) performs the highest thermal performance factor up to 1.2, 0.9 and 0.85 at Reynolds number of 6000.