226 H^∞制御系設計法を用いた磁気ディスク装置の外乱抑圧制御に関する研究
川福 基裕野々山 和徳平井 洋武小林 正人奥山 淳
著者情報
会議録・要旨集 フリー

p. 224-225

詳細
抄録
This paper describes designing a controller of a hard disk drive for rejecting disturbances using mixed sensitivity approach. Position Error Signal (PES) is consist of Repeatable Runout (RRO) and Non-Repeatable Runout (NRRO), NRRO is decomposed into its contributing component which are force disturbance, mechanical vibration, and etc, in frequency domain. To simulate the behavior of the disturbance signals, the decomposed signals are transformed to time domain. The H^∞ control design can be eliminated such disturbances effectively. A mixed sensitivity approach is applied to the robust controller design of the track-following control for the HDD. We compare between the results with a conventional controller and the results with the proposed controller. it shows the validity of the proposed controller design method.