日本機械学会関東支部総会講演会講演論文集
Online ISSN : 2424-2691
ISSN-L : 2424-2691
セッションID: 21114
会議情報
21114 動吸振器を利用した電磁誘導型発電システムに関する研究(情報・知能・精密機器)
池田 大輔関口 達郎藤本 滋
著者情報
会議録・要旨集 フリー

詳細
抄録
Power generation research using a variety of structure and machine vibrations is carried out in various institutions. Simultaneously, research with vibration suppression equipment is also being performed and there are numerous examples being put into practical use. This paper will describe a basic examination to determine the effectiveness of power generation and the attenuation effect when using a vibration power generator in a footbridge dynamic damper. Experiments were carried out with a power generation element to determine the basic characteristics of power generation and vibration using an electromagnetic induction-type power generation element. It was confirmed that voltage generation is almost proportional to velocity and the generated voltage has nearly no frequency dependency, while the effect of attenuation can be achieved by installing a resistor.
著者関連情報
© 2007 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top