Proceedings of International Conference on Leading Edge Manufacturing in 21st century : LEM21
Online ISSN : 2424-3086
ISSN-L : 2424-3086
2003
会議情報
314 Optical Telemeter System of Rotating Spindle Temperature by Adopting One-chip Micro-controller : Development of the System and Measurement Accuracy
K. YokoyamaY. NagaiT. SuzukiS. KobayashiT. Kodera
著者情報
会議録・要旨集 フリー

p. 489-494

詳細
抄録
This paper deals with the development of the optical telemeter system, in which thetemperature of rotating spindle is measured with thermo-couple and the output is A/D converted and the digital data is transmitted from LED on the rotating head as optical data series. The size decreasing of the rotating head is achieved by three methods; the adoption of one-way data-transmission from the rotating head toward the stationary head, the adoption of one-chip micro-controller and the adoption of digital-filtering process in personal computer of stationary side. The measurement accuracy of the developed system is superior than 0.1--0.05℃ for 0--50℃ range. The data transmission rate is 6,200data/s of 12 bits data. And power for electric circuit in the rotating head is supplied by non-contact electro-magnetic phenomenon.
著者関連情報
© 2003 The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top