年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: J0510101
会議情報
J0510101 灌流液温度差情報を利用した肝臓内流動分布の可視化([J051-01]流れの高次元化可視化に向けて(1),流体工学部門)
小原 弘道松野 直徒森戸 規之絵野沢 伸水沼 博
著者情報
会議録・要旨集 フリー

詳細
抄録
The machine perfusion (MP) technique can expand the donor pool for organ transplantation. The MP technique is able to eliminate toxins generated from cells and provide nutrition and oxygen to the tissues via the continuous supply of the preservation perfusate. Furthermore, the organ viability can be evaluated using screening techniques during MP before implantation in a recipient. In this study, the new visualization technique to evaluate the organ conditions of the flow distribution is proposed and discussed using porcine donated livers. This technique is employed the temperature difference of the perfusate for organ preservation to visualized the portal vein flow distributions during machine perfusion. As results, the flow distributions in the liver and the transitions of the temperature at the each measurement points can indicate the organ functions before implantation.
著者関連情報
© 2014 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top