J0320101 液化水素型水素スタンド併設給油取扱所におけるHAZID解析とETAを用いた損傷発生確率の検討
佐藤 龍之介中山 穣坂本 惇司笠井 尚哉澁谷 忠弘三宅 淳巳
著者情報
会議録・要旨集 フリー

詳細
抄録
In recent years, there has been a growing momentum to the hydrogen energy spread. One of use of effective hydrogen energy is a fuel cell vehicle, therefore development and social implementation of fuel cell vehicles has been promoted. One of the challenges of social implementation of fuel cell vehicles is the establishment of safe hydrogen fueling stations. This solution is a safety assessment in hydrogen fueling stations. Safety measures must be incorporated into the stations. In this study, from the results of HAZID analysis, we made an examination of probability by ETA and estimated the influence of the safety measures in hydrogen fueling stations. As a result, we were successful in the quantitatively evaluation of the impact of safety measures that were unclear in the HAZID analysis. And we confirmed the validity of the results of HAZID analysis in the hybrid gasoline-liquid hydrogen fueling stations and Usefulness of HAZID analysis in the safety evaluation of hydrogen fueling stations.