年次大会講演論文集
Online ISSN : 2433-1325
会議情報
2310 新型 HAT サイクルの性能検討
飛田 健一幡宮 重雄伊藤 悦子
著者情報
会議録・要旨集 フリー

p. 379-380

詳細
抄録
The Humid Air Turbine (HAT) cycle is expected to have high efficiency and low cost. Performance of the Advanced HAT cycle, which is the improved type of HAT cycle, was studied by the heat and mass balance analysis in this paper. It is investigated particularly what effects the performance of each component have on the generating power and the thermal efficiency of the cycle. As a result, the information which is needed to optimalize the Advanced HAT cycle was obtained. The pressure ratio 15 and the humidifier ratio around 16 wt.% is the best condition at the turbine inlet temperature 1300℃
著者関連情報
© 2000 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top