2105 高性能セパレータの開発 (2) 改良型低圧損セパレータの性能確認試験
山崎 之崇近藤 隆久奈良林 直師岡 慎一西田 浩二福田 俊彦坂下 彰浩水谷 淳
著者情報
会議録・要旨集 フリー

p. 163-164

詳細
抄録
In order to verify the two-phase flow simulation method, 1/2.22 scale test section was used for high-pressure two-phase flow test. The pressure characteristics and the separating performance of the improved swirler designed by two-phase simulation method are also verified by 1/2.22 scale model experiment. It is found that the improved swirler can decrease pressure losses by about 59 percent compared to the conventional swirler and it can almost keep the same discharged water rate as the conventional swirler. We confirmed that the separator system with the selected swirler can decrease pressure losses more than 20 percent compared to the total pressure losses of the conventional separator without decreasing the discharged water rate by 1/2.22 scale-model experiment.