年次大会講演論文集
Online ISSN : 2433-1325
会議情報
3244 μTAS 用パッシブミキサーの数値設計 : 第一報, 曲線座標変換法および流動解析
新宅 博文川野 聡恭神野 伊策小寺 秀俊
著者情報
会議録・要旨集 フリー

p. 325-326

詳細
抄録
Miniaturized biochemical analysis systems, so-called a μTAS, have gained considerable interest for research and development in new-bio-engineering. However, there is a difficulty in mixing fluids in the micro device because of extremely low Reynolds number. So, to develop an effective micromixer which can fully perform at low Reynolds number flow is important to realize integrated μTAS. In our previous experiment based on flow visualization technique, it was found that the diffusion phenomena of two species must play an important role in mixing process in such a creeping flow. The effect of diffusion should be investigated in detail to evaluate the performance of passive mixer. In this paper, we make a numerical study on the suitable flow condition for μTAS and the diffusion characteristics of passive mixer by means of curvilinear coordinate transformation technique.
著者関連情報
© 2003 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top