S0503-1-7 縦流換気対面通行道路トンネルにおけるジェットファンインバータ制御の基礎研究(トンネルの空気力学、換気、火災(1))
中堀 一郎阿藤 隆英村上 健一荒木 大輔三谷 敦史
著者情報
会議録・要旨集 フリー

詳細
抄録
Modern, general-purpose inverters have developed to a stage where they can be used reliably and with very little maintenance in environments such as road tunnels. It is shown in this paper that their use to enable jet-fans to be operated at reduced speed could yield large cost savings and other benefits for tunnel operators and users. The potential cost savings arise primarily from greatly reduced power demand and are therefore beneficial from a global wanning perspective as well as for tunnel operators. Greatest cost savings are shown to be achieved when all jet-fans in a tunnel are operated at reduced speed rnstead of operating a smaller number at high speed. The methodology is validated through full-scale field tests.
著者関連情報
© 2009 一般社団法人日本機械学会