年次大会講演論文集
Online ISSN : 2433-1325
セッションID: K-1037
会議情報
K-1037 スノーシェッドを有する断続トンネル間における換気の干渉(G05-8 トンネル火災など(1))(G05 流体工学部門一般講演)
佐野 彰紀川端 信義石川 拓司
著者情報
会議録・要旨集 フリー

詳細
抄録
If fire smoke is generated in the upstream successive tunnel by a traffic accident, the exhausted smoke flows into the downstream tunnel, which may destroy the evacuate environment in the downstream tunnel. It is, therefore, important to discuss the interference rate of successive tunnels. In this paper, the effect of variouse parameters on the interference rate is investigated by large eddy simulation. The reliability of numerical code is verified by comparing with the real scale tunnel experiment. Consequently, the interference rate is expressed by a new equation.
著者関連情報
© 2001 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top