1010 配管の熱疲労評価法の高度化に関する研究 : (2)熱荷重の評価のための流体温度変動の熱流動ベンチマーク解析(OS10-3 供用エネルギー機器の経年変化と健全性評価-熱疲労-)
中村 晶銭 紹祥田中 正暁笠原 直人
著者情報
会議録・要旨集 フリー

詳細
抄録
Thermal fatigue crack may initiate at mixing tee where high and low temperature fluids flow in and mix. This paper shows some results of numerical simulations that were conducted to evaluate temperature fluctuation in mixing tee using some turbulence models. Accuracy of these simulations was examined for a velocity condition of WATLON experiments performed at Japan Atomic Energy Agency: wall jet condition that the jet from the branch pipe flowed along the main pipe wall. Time-averaged temperature distribution with LES and DES agreed well with the experimental results, but the intensity of temperature fluctuation in the wake ofjet had some differences. RANS model, such as SST model, can't simulate the fluctuation around the jet although the same mesh, boundary conditions and time step were used in the calculation.
著者関連情報
© 2010 一般社団法人 日本機械学会