M&M材料力学カンファレンス
Online ISSN : 2424-2845
セッションID: OS0823
会議情報
OS0823 混合ガス燃焼時の配管強度に関する研究 : 第2報 : 燃焼時の配管強度解析
根布 景堂崎 浩二日高 章隆曽根 孝浩藤井 正熊谷 直己内田 正宏
著者情報
会議録・要旨集 フリー

詳細
抄録
The detonation of mixed hydrogen and oxygen gas accumulated in the piping of boiling water reactors causes high pressure, about 20 times higher than initial pressure. We investigated a method for evaluating the strain of piping subjected to internal detonation by using FEM analysis. An experiment of pipe specimens subjected to the internal detonation of H_2-O_2 gas was analyzed by our analysis method. The pressure of the detonation wave was estimated by computational fluid dynamics analysis, and this pressure was loaded on the internal surface of an FEM pipe model. The stress-strain relationship obtained by a high strain rate tensile test was used in an FEM analysis. The analytical results of plastic strain were equivalent to or higher than the experimental results. We concluded that our analytical method conservatively estimates the strain of piping subjected to internal detonation.
著者関連情報
© 2012 一般社団法人 日本機械学会