放射光X線CTを用いたはんだ接合部の非破壊ひずみ計測
*東方 浩紀釣谷 浩之佐山 利彦岡本 佳之高柳 毅星野 真人上杉 健太郎森 孝男
著者情報
会議録・要旨集 フリー

詳細
抄録

In the present study, a synchrotron radiation micro CT and digital image correlation (DIC) were applied to the measurement of the strain distribution in solder joints due to thermally cyclic loading. At first, in order to verify the accuracy of the measured strains, DIC was applied to artificially deformed images. As a result, it was possible to measure the strain with an error of 18% with respect to the artificially loaded strain 0.01. Next, DIC was applied to the CT images of a flip-chip type joined specimen loaded by thermal cycles and the strain distributions were measured. Consequently, we succeeded in measuring the strain at the region where the characteristic microstructures such as the Ag3Sn phase are distributed.