「運動と振動の制御」シンポジウム講演論文集
Online ISSN : 2424-3000
会議情報
313 減衰係数切替え型セミアクティブオイルダンパを適用した超高層建物の振動実験
清水 幹栗野 治彦田上 淳
著者情報
会議録・要旨集 フリー

p. 370-373

詳細
抄録
The semi-active oil damper described in this paper switches is damping coefficient from maximum to minimum and dissipates twice as much energy as an ordinary passive damper. Its performance has been already verified under both dynamic loading tests with the full-scale device and the forced vibration test on the mid-rise building which was the first building with this semi-active oil damper. In order to verify the performance of this semi-active oil damper under low frequency and small vibration, forced vibration test was conducted on a high-rise building whose first natural period is over 4sec. The results showed that the damper added a lot of damping even at a very small stroke, about 0.1mm.
著者関連情報
© 2003 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top