機械材料・材料加工技術講演会講演論文集
Online ISSN : 2424-287X
セッションID: 522
会議情報
522 圧電素子を用いた小型疲労試験機の開発とNi基金属ガラスの疲労特性(OS 先端材料の力学特性と計測技術(1))
八町 順早乙女 康典石田 央竹田 英樹西山 信行井上 明久
著者情報
会議録・要旨集 フリー

詳細
抄録
We developed a small fatigue testing machine using a Piezoelectric actuator. The fatigue testing machine was designed on the concept of micro-factory. Fatigue tests have been carried out on high strength Ni-based metallic glass. The fatigue strength of the material is about 350MPa, and this strength is 13% of the tensile strength of 2.7GPa. Fracture has been occurred for a moment due to the glassy structure after the crack propagation initiated at the inside of a specimen. Striation due to the crack propagation during the reated cycles has been observed and the vein pattern has been recognized at the fractured surface.
著者関連情報
© 2004 一般社団法人 日本機械学会