動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: FP1-04
会議情報
プラズマ溶射遮熱コーティングシステムの室温ならびに高温における機械的損傷挙動の微視的様相(FP1 高温・高効率発電・エネルギー貯蔵技術)
高橋 智古葉 正行原田 良夫
著者情報
会議録・要旨集 フリー

詳細
抄録
In situ observation of the mechanical failure behavior was conducted for different kinds of the plasma sprayed thermal barrier coating (TBC) systems by means of an optical microscopy under the static loadings at ambient temperature and 900℃; as the most fundamental aspect, in order to clarify the failure mechanism of TBCs. Several kinds of TBC systems were prepared by using different coating parameters such as the sorts of top-coat powder, heat-treatment condition and so forth. Mechanical tensile or compressive loading was applied progressively to the TBC specimen in the axial loading test. The influence of TBC microstructure and testing temperature on the crack initiation and propagation behavior was investigated in detail. Furthermore, the TBC failure was quantitatively evaluated in relation with the mechanical strain applied on TBC systems.
著者関連情報
© 2004 一般社団法人 日本機械学会