動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: C101
会議情報
C101 ガスタービン吸気冷却システム(OS9 熱・流動(1))
内田 竜朗大友 文雄福武 英紀伊東 正雄鹿目 浩正奥野 研一
著者情報
会議録・要旨集 フリー

詳細
抄録

This paper describes a gas turbine inlet air cooling system using high pressure spray nozzle Scale model inlet duct is manufactured within water spray of inlet fogging system, and many testing was conducted on the condition of same level of actual velocity with inlet duct at site As testing results, droplet size finally reduce to SMD 80 um at 1st blade leading edge Next, water spray adjusting actual attack to blade is provided to test piece of same material with actual compressor blade, and weigh is measured at every constant time period for getting averaged erosion depth As a result, it is concluded that erosion at leading edge of 1st compressor blade is predicted to be approx 1.2mm at maximum per 10 years less than acceptable limit of depth, and it may have no need for maintenance of blade replacement and so on in 10 years

著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top