D112 テーパ型スタックによる熱音響装置の性能向上(OS8 外熱機関・廃熱利用技術(1))
竹山 大基塩山 勉星野 邦雄渡邉 勝信
著者情報
会議録・要旨集 フリー

詳細
抄録
We are developing a highly efficient thermoacoustic system that is capable of using industrial waste heat efficiently. In this study, we have designed a taper stack, for the thermoacoustic system, in which the cross sectional area increases toward the axial direction. Theoretically, the smaller the taper ratio, the prime mover efficiency improves compared with the efficiency of a straight prime mover. The efficiency of thermoacoustic energy conversion was examined for a taper prime mover and cooler with a taper ratio of 0.75. The specific Carnot efficiency of prime mover improved to 1.85 times whereas that for a straight by experiment.
著者関連情報
© 2014 一般社団法人 日本機械学会