柏崎刈羽6・7号機用フィルタ装置の性能評価試験
(3)よう素ガスの除染係数の計測
橋本 浩二佐々 大輔渡邉 史紀大森 修一木村 剛生村井 荘太郎川村 慎一
著者情報
会議録・要旨集 フリー

詳細
抄録

After the Fukushima Daiichi nuclear disaster, Tokyo Electric Power Company (TEPCO) launched a project to develop the Filtered Containment Venting System (FCVS), in which our very bitter experiences in the accident are reflected. One of the main purposes of the development of the FCVS is to enhance operability of venting under the severe plant conditions such as the SBO during progressing of severe core damage, and another is to enhance removal performance of radio-nuclides with the newly added filtering equipment, which is installed in the venting line from the PCV to the outer. The Kasshiwazaki-Kariwa NPS unit 6 and 7 are the first reactors applied the FCVSs. Performance of the FCVS has been verified by an extensive test program which includes scaled filter venting test under various conditions. In this paper we show schematic of our test facility and some test results on Iodine gas decontamination factor (DF). The test results clearly show that the DF of the system is above the FCVS design target value (DF>1000).