熱工学講演会講演論文集
Online ISSN : 2433-1317
会議情報
A231 溶融錫液柱内の振動型マランゴニ対流の開始条件
今石 宣之安廣 祥一依田 真一
著者情報
会議録・要旨集 フリー

p. 301-302

詳細
抄録
The new simulation results revealed that the conductive heat transfer through the small gaps (1mm in total) between the melt/rod interface and the temperature measuring points causes significant temperature drop which provide with serious error in estimating Marangoni numbers. This conductive temperature drop is the major reason of the discrepancy between the numerical results in preceding years and the experimental results obtained in NASDA. The effect of the finite conductivity of the rods causes additional effect through the non-uniform temperature distributions on the melt/rod interface. This effect is not negligible but yet minor.
著者関連情報
© 2002 一般社団法人日本機械学会