F212 高低温水合流部の高サイクル熱疲労評価に関する研究 (1) : 設計基準チャート (1)、 (5);無次元温度変動減衰特性と外乱補正係数
若松 光夫椎名 孝次谷本 浩一福田 俊彦南 安彦守屋 祥一
著者情報
会議録・要旨集 フリー

p. 479-480

詳細
抄録
Temperature fluctuation or thermal striping are considered in the hot and cold water mixing tees under plant piping systems, for example residual heat removal system of light water reactor (LWR). In order to draft the Japan Society of Mechanical Engineers (JSME) code concerning high-cycle thermal tatigue of piping systems, studies of thermal striping in the mixing tees has been conducted. Visualization tests and water temperature fluctuation measured tests were carried out in three type mixing tees. Large temperature fluctuation amplitude, ΔTpp=0.9∿1(ΔTrms=0.2∿0.3), occurred at near the junction of mixing tees in Type-A and Type-B. And the distance downstream from the tee junction increased, the fluid temperature fluctuation decreased. Flow pattern and temperature fluctuation almost depend on the velocity ratio. The effect of the main flow velocity was considered to be small. From these experimental results, temperature fluctuation reduction constant (β) characteristics (design chart(1)) were evaluated in several type mixing tees under velocity ratio and main velocity. The effects of upstream piping elements, elbow, valve and diffuser, were small. So piping element compensate constants (η) are about 1.