熱工学講演会講演論文集
Online ISSN : 2433-1317
会議情報
F214 高低温水合流部の高サイクル熱疲労評価に関する研究 (3) : 設計基準チャート (4);レインフローを用いた周波数特性
谷本 浩一小倉 健志椎名 孝次福田 俊彦南 安彦守屋 祥一
著者情報
会議録・要旨集 フリー

p. 483-484

詳細
抄録
Thermal Striping tests in mixing tees with hot and cold water were conducted for three types of flow conjunctions in order to establish an evaluation method for high-cycle thermal fatigue of piping systems. The main tests were temperature fluctuation measurement tests carried out using metal pipes to evaluate frequency characteristics of temperature fluctuation. By FFT analysis, dominant frequency of temperature fluctuation was not observed. Design charts for evaluation stress fatigue have been prepared by using the rain flow method.
著者関連情報
© 2002 一般社団法人日本機械学会